LaCie blue eye pro Calibrating LaCie 300/500/700 Series Monitors
User Manual page 23
Saving the Calibration Report5.3.3.
The Calibration Report can be saved by clicking on the Save
button. The Save As window then appears. After choosing a
name, location and format (PDF- , Html-, Text-,) to save the file,
click on the Save button and the software will create and display
a document containing a detailed Monitor Calibration Report.
5.3.4. The Calibration Report
These first lines (a) indicate the date on which the calibration
took place, the path of your saved profile on the system and its
name (in this case 23.05.06-5000K- 22-100cd).
These two diagrams (b) show the Chromaticity diagram and the
delta-E differences between measured color patches and tar-
geted values.
These lines (c) represent your calibration settings targets versus
the results obtained. Differences in percentage are also dis-
played This value represents the luminance of the black color
displayed by the monitor.
This table (d) summarizes the measurements taken of the grey-
scale displayed by your monitor. For each line, you will find:
Color – the shade of gray measured
Kelvin – the temperature of the measured color
Chroma the chromaticity difference between the mea-
sured color and target color
Gamma the Gamma value of the curve on which the
point belongs
Average Gamma (e) the average of the values given in the
Gamma table: This is the average of the values given in the
gamma column.
a
b
c
d
e